0

Out of 0 Ratings

Owner's of the Broan Ventilation Hood Broan Ventilation Hood gave it a score of 0 out of 5. Here's how the scores stacked up:
  • Reliability

    0 out of 5
  • Durability

    0 out of 5
  • Maintenance

    0 out of 5
  • Performance

    0 out of 5
  • Ease of Use

    0 out of 5
of 36
 
- 8 -
5. INSTALL THE HOOD
!
6. CONNECT WIRING
Connect cable into wiring box using provided wire connectors.
Connect wires as follows: BLACK to BLACK, WHITE to WHITE and
GREEN or BARE wire under GREEN ground screw. DO NOT FORGET TO
CONNECT THE GROUND.
WARNING
Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with
all applicable codes and standards. Before connecting wires, switch power off at service panel
and lock service disconnecting means to prevent power from being switched on accidentally.
!
5.1 Run power cable to installation location. Position the hood in its intended location. Using a pen, mark the position
of the screws (smaller part of the keyholes, see pictures below for the (5) keyholes locations). Remove the hood.
5.2 Install (4) no. 8 x 1/2’’ screws, leaving a 1⁄8’’ gap (do not install the no. 5 screw yet).
5.3 Attach the wire clamp, insert the power cable in the hood and tighten the wire clamp to secure the cable. Place
the hood under the cabinet and slide it in position. Make sure the adapter/damper assembly enters the duct
opening. Tighten the (4) screws completely, then add the last screw (screw no. 5) in the center keyhole. Make sure
the damper flap opens freely.
HD0115
1
2
HD0122
1
2
3
5
4
HD0123
3
4
HD0123
GROUND
SCREW