0

Out of 0 Ratings

Owner's of the Broan Ventilation Hood Broan Ventilation Hood gave it a score of 0 out of 5. Here's how the scores stacked up:
  • Reliability

    0 out of 5
  • Durability

    0 out of 5
  • Maintenance

    0 out of 5
  • Performance

    0 out of 5
  • Ease of Use

    0 out of 5
of 36
 
- 7 -
4. INSTALL THE ADAPTER/DAMPER
The wall duct must be roughed-in to properly interface with the hood. Before performing the installation, make sure the
adapter fits easily in the duct. If this hood replaces an existing hood, please note that location of the air exhaust can
vary from one hood manufacturer to another.
NOTE: If using the optional adaptor 3¼” x 14” to 3¼” x 10” model T461, discard the provided adapter/damper and
perform step 4 with the optional adaptor T461.
4.1 Fold down the foldable flange of the adapter/damper. This flange must
be at 90° from the remaining flanges. See picture beside.
F
OR HORIZONTAL DISCHARGE ONLY:
4.2 Using three (3) no. 6 x 1/2’’ screws provided, secure the adapter to the
back of the hood. Remove tape from damper flap.
4.3 Seal the adapter and the metal shutoff plate to the hood using duct tape.
F
OR VERTICAL DISCHARGE ONLY:
4.4 Using three (3) no. 6 x 1/2” screws provided, secure the adapter to
the top of the hood. Remove tape from damper flap.
4.5 Seal the adapter and the metal plate to the hood using duct tape.
HD0112
HO0037
HD0113
HO0033
HO0038