STEP 2: SURFACE BURNERS
To replace the nozzles of the surface burners, lift
up the burners and unscrew the nozzles shipped
with the range using a 7 mm {socket wrench).
Replace nozzles using the conversion set supplied
with the range or by a Bertazzoni authorized
parts warehouse. Each nozzle has a number
indicating its flow diameter printed on the body.
Consult the table on page 20 for matching nozzles
to burners.
STEP 3: MINIMUM FLAME ADJUSTMENT
WARNING!
These adjustments should be made only for use
of the appliance with natural gas. For use with
liquid propane gas, the choke screw must be
fully turned in a clockwise direction.
SURFACE BURNERS
1. Light one burner at a time and set the knob
to the MINIMUM position (small flame).
2. Remove the knob.
3. The range is equipped with a safety valve.
Using a smallsize slotted screwdriver, locate
the choke valve on the valve body and turn
the choke screw to the right or left until the
burner flame is adjusted to desired minimum.
4. Make sure that the flame does not go out
when switching quickly from the MAXIMUM
to the MINIMUM position.